Reproducibility of Replicated Trabecular Bone Structures from Ti6Al4V Extralow Interstitials Powder by Selective Laser Melting
Yazarlar (5)
Dr. Öğr. Üyesi Arif BALCI Kafkas Üniversitesi, Türkiye
Furkan Küçükaltun Gazi Üniversitesi, Türkiye
M. Fatih Aycan Gazi Üniversitesi, Türkiye
Yusuf Usta Gazi Üniversitesi, Türkiye
Teyfik Demir Tobb University of Economics And Technology, Türkiye
Devamını Göster...
Makale Türü Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Arabian Journal for Science and Engineering (Q2)
Dergi ISSN 2193-567X Dergi Bilgileri (2021)
Dergi Tarandığı Indeksler SCI-Expanded
Makale Dili İngilizce Basım Tarihi 01-2021
Cilt / Sayı / Sayfa 46 / 3 / 2527–2541 DOI 10.1007/s13369-020-05145-7
Makale Linki http://dx.doi.org/10.1007/s13369-020-05145-7
UAK Araştırma Alanları
Malzeme Tasarım ve Davranışları Üretim Teknolojileri
Özet
The field of orthopedic regenerative medical studies has begun to use porous metal structures for biomedical implants, which have lower strength and ingrowth behavior, similar to bones. It is possible to produce such porous metal structures with a designable microarchitecture or replicated topology by additive manufacturing. The main purpose of using these artificial pore geometries in the biomedical field is to increase the biocompatibility of the product by imitating the bone. In this study, bone samples from the femoral and vertebral regions of a sheep were obtained and scanned by microfocus computed tomography (Micro-CT). Trabecular bone models were produced from Ti6Al4V extralow interstitials powder using the selective laser melting with 1:1, 1:1.25, and 1:1.50 scales. The produced samples were scanned using Micro-CT, and 3D models were formed. The 3D models of the trabecular bone and samples were aligned in a computer environment to determine deviations in both size and angle of arms in the trabecular structure. It was found that the deviations decreased when the angle was above 60°, whereas they significantly increased with the size below 150 microns. The size distribution and interconnectivity ratio of the pores formed in the production was obtained from the PNMs. It was determined that the mean equivalent diameters of vertebra and femoral pores, from the pore network models are 767 ± 265 µm and 623 ± 245 µm, and concluded that the samples produced in the scale of 1: 1 and 1: 1.25 could represent the pore size distribution in the bone.
Anahtar Kelimeler
Additive manufacturing | Porous metals | Selective laser melting (SLM) | Trabecular bone
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Yöksis 3
Scopus 7
Reproducibility of Replicated Trabecular Bone Structures from Ti6Al4V Extralow Interstitials Powder by Selective Laser Melting