img
Monitoring tyrosinaemia type I: Blood spot test for nitisinone (NTBC)   
Yazarlar
Özet
BACKGROUND Quantification of nitisinone, 2-(nitro-4-trifluoromethylbenzoyl)1,3-cyclohexanedione (NTBC) has been repeatedly described. Nevertheless monitoring of NTBC has not yet become part of routine therapy surveillance in tyrosinaemia type I (OMIM 276700). We developed a blood spot test to facilitate collection and transport of samples. Furthermore, the test material can be used for determination of other parameters like tyrosine and succinylacetone. METHOD For quantification of NTBC in blood spots filter paper discs of 3.2mm diameter were extracted with 150μL methanol containing mesotrione as internal standard (IS). Analysis was done by UPLC--MS/MS on a Xevo mass spectrometer (ESI+), (MRM). Parent ions were 330.05 for NTBC and 340.05 for IS, daughter ions were m/z 217.95 and m/z 125.95 for NTBC, and m/z 227.95 and m/z 103.95 for IS. RESULTS The calibration curve for NTBC in blood ...
Anahtar Kelimeler
Blood spot testing | Monitoring therapy | Nitisinone | NTBC | Tyrosinaemia type I | Tyrosine
Makale Türü Özgün Makale
Makale Alt Türü SSCI, AHCI, SCI, SCI-Exp dergilerinde yayımlanan tam makale
Dergi Adı Clinica Chimica Acta
Dergi ISSN 1873-3492
Dergi Tarandığı Indeksler
Dergi Grubu Q2
Makale Dili İngilizce
Basım Tarihi 01-2011
Cilt No 412
Sayı 1
Sayfalar 134 / 138
Doi Numarası 10.1016/j.cca.2010.09.027
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
SCOPUS 25
Monitoring tyrosinaemia type I: Blood spot test for nitisinone (NTBC)

Paylaş