Electrochemical Impedance Spectroscopy (EIS) Principles and Biosensing Applications (Handbook of Nanobioelectrochemistry)   
Yazarlar
Hilmiye Deniz Ertuğrul Uygun
Dokuz Eylül Üniversitesi, Türkiye
Doç. Dr. Zihni Onur UYGUN Doç. Dr. Zihni Onur UYGUN
Kafkas Üniversitesi, Türkiye
Özet
Electrochemical impedance spectroscopy (EIS) used in biosensor systems is a label-free measurement method used in the measurement of electrochemical reactions. With this method, electrode surface characteristics, surface kinetics, and mass transport transfer can be measured. All these measurements can be performed with a single method.With EIS, the electrochemical circuit diagram of the surface can be drawn by scanning starting from a certain frequency. With this circuit diagram, the surface of the electrode can be seen electrochemically. In addition to the electrochemical measurement, it is actually possible to obtain strong mathematical data. All of this mathematical data can be verified by experimental measurements and provides opportunities to verify experimental results. In this way, there are both modifications in the development of biosensors and the possibility of quantitative measurement. This makes the system one step ahead of other methods in biosensor applications. The use of time as a function of this measurement made with alternating current also increases the sensitivity of the measurement. In this frequency measurement, the resistance of the electrode surface is measured as impedance and more suitable results are obtained. In biosensor applications, since the resistance of the electrode surface is measured in ohms, it is also important to process the data obtained afterward, to find the appropriate circuit model optimize the non-faradaic measurements, and how the measurement is optimized within the redox probe. For this reason, this measurement system, which is seen as a simple surface resistance measurement, is actually seen as a very complex and knowledge-based method. Therefore, the advantages are extremely numerous. Among the most important advantages of EIS are its fast electrode kinetics, the detection of non-electroactive species, and its power to perform measurements without the need for microscopic surface imaging techniques. In this book chapter, the application of EIS in biosensors, calculation methods, and different sub-applications are evaluated.
Anahtar Kelimeler
Affinity biosensors | Biosensor | Chronoimpedance | Electrochemical impedance spectroscopy
Kitap Adı Handbook of Nanobioelectrochemistry
Bölüm(ler) Electrochemical Impedance Spectroscopy (EIS) Principles and Biosensing Applications
Kitap Türü Kitap Bölümü
Kitap Alt Türü Alanında uluslararası yayımlanan kitap bölümü
Kitap Niteliği Scopus indeksinde taranan bilimsel kitap
Kitap Dili İngilizce
Basım Tarihi 01-2023
ISBN 978-981-19-9436-4
Basıldığı Ülke Singapur
Basıldığı Şehir
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
SCOPUS 2
Google Scholar 3
Handbook of Nanobioelectrochemistry

Paylaş