This study investigates the seismic behavior and collapse mechanisms of the historical Sheik Ali Mosque in Antakya, Türkiye, which was heavily damaged during the 2023 Kahramanmaraş Earthquakes. A detailed three-dimensional finite element (FE) model of the mosque was developed, incorporating nonlinear material properties, to perform both pushover and nonlinear dynamic time-history analyses. The pushover analysis revealed lateral load capacities of approximately 12,000 kN in the longitudinal (X) direction and 10,500 kN in the transverse (Z) direction, with collapse displacements around ± 20 mm. Modal analysis showed a first mode frequency of 1.81 Hz for the minaret and 5.64 Hz for the main dome, consistent with field-based estimations. The analysis results revealed that the minaret exhibited significant displacement prior to the main structural elements and likely initiated the collapse … |