Evaluation of the Ocular Surface in Different Contact Lens Replacement Schedules
Yazarlar (6)
Doç. Dr. Ersin MUHAFİZ Kafkas Üniversitesi, Türkiye
Hasan Ali Bayhan Yozgat Bozok Üniversitesi, Türkiye
Prof. Dr. Sevinç Şahin Yozgat Bozok Üniversitesi, Türkiye
Prof. Dr. Ayşe Yeşim Göçmen Yozgat Bozok Üniversitesi, Türkiye
Seray Aslan Bayhan Yozgat Bozok Üniversitesi, Türkiye
Canan Gürdal
Türkiye
Devamını Göster...
Makale Türü Özgün Makale (SSCI, AHCI, SCI, SCI-Exp dergilerinde yayınlanan tam makale)
Dergi Adı Cornea (Q1)
Dergi ISSN 0277-3740 Dergi Bilgileri (2019)
Dergi Tarandığı Indeksler SCI-Expanded
Makale Dili İngilizce Basım Tarihi 05-2019
Cilt / Sayı / Sayfa 38 / 5 / 587–594 DOI 10.1097/ICO.0000000000001870
Makale Linki http://dx.doi.org/10.1097/ico.0000000000001870
UAK Araştırma Alanları
Göz Hastalıkları
Özet
Purpose:
To evaluate the effects of different contact lens (CL) replacement schedules and different CL materials on the ocular surface and tear function.


Methods:
Daily disposable hydrogel CLs were given to group 1 (n = 22), daily disposable silicone hydrogel CLs were given to group 2 (n = 25), and reusable silicone hydrogel CLs were given to group 3 (n = 24). Tear function tests and inflammatory cytokine [interleukin (IL)-6, IL-8, IL-17A, and matrix metalloproteinase (MMP)-9] levels were evaluated before and at 1 and 3 months after CL usage. Impression cytology was evaluated before and at 3 months after CL usage.


Results:
At the first and third months of CL usage, a statistically significant difference was determined between the groups in the levels of IL-6, IL-8, and IL-17A in tears, with the lowest levels in group 1 and the highest levels in group 3 (all P < 0.05). At the third month of CL usage, the levels of these cytokines (in picograms/milliliter) were 6.06 ± 0.83, 78.18 ± 12.42, 61.69 ± 13.95, and 37.71 ± 5.95 in group 1 and 8.04 ± 0.89, 107.34 ± 14.40, 68.63 ± 13.72, and 46.26 ± 6.50 in group 3, respectively. A statistically significant decrease was determined over time in the Schirmer test in group 1, in only the tear breakup time in group 2, and in the tear breakup time and Schirmer test in group 3 (all P < 0.05). A statistically significant increase was determined over time in the levels of IL-6, IL-8, IL-17A, and MMP-9 in all groups. In the third month, a significant progression was observed in the Nelson grade (P < 0.05) in all groups.


Conclusions:
The wear of daily disposable CLs can be considered to cause less damage to the ocular surface and less increase in proinflammatory cytokine levels.
Anahtar Kelimeler
BM Sürdürülebilir Kalkınma Amaçları
Atıf Sayıları
Yöksis 2
Evaluation of the Ocular Surface in Different Contact Lens Replacement Schedules